The periodic report for class C and D devices, structured so the benefit-risk conclusion follows from sales, incident and performance data for the period.
The PSUR lists data but draws no conclusion
Article 81 asks class C and D manufacturers for three things on top of the PMS data: the conclusions of the benefit-risk determination, the main findings of the PMPF, and the volume of sales with an estimate of the population using the device. A PSUR that tabulates complaints without those three elements does not meet the article, however long it is.
The template follows the reporting cycle: identification and devices covered, sales and exposure, serious incidents and FSCAs, erroneous results and complaints, trends, literature, PMPF findings, the benefit-risk conclusion and the actions for the next cycle, with a compliance checklist against Article 81.
- Word .docx
- Fully editable
- Class C and D
- Article 81 checklist
- Instant download
Scope
What the template covers
Every element Article 81 requires, plus the analysis that makes the conclusion defensible.
01
Data for the period
Sales volume and exposure, data collected, serious incidents and FSCAs, non-serious incidents, erroneous results and complaints.
02
Analysis
Trend analysis, literature, databases and registers, similar devices, indicators against thresholds, performance studies and PMPF findings.
03
Conclusion and actions
Benefit-risk conclusion, preventive and corrective actions, impact on the QMS, actions for the next cycle and the submission route.
Contents
Twenty-one chapters and an Article 81 checklist
Audience
Who the template is for
- Manufacturers of class C and D IVDs
- PMS and vigilance teams producing the yearly report
- Consultants reviewing PSURs before notified body submission
Class A and B devices need a PMS Report under Article 80, not a PSUR. The PMS Report template is in the same kit.
What is included
What you get when you buy
- One Word template
- Tables for sales, incidents, complaints and trends
- A section for each Article 81 element
- A compliance checklist against Article 81
Questions
Before you buy
Do I need a PSUR for a class B device?
No. Class A and B devices need a PMS Report under Article 80. The PSUR is for class C and D.
How often is it updated?
At least annually for class C and D. For class D it is submitted to the notified body through the electronic system; for class C it is made available to the notified body.
Does it connect to the PMS Plan?
Yes. It uses the indicators and thresholds the PMS Plan defines. Both are in the IVDR Performance Evaluation Kit.
Can I buy the full kit instead?
Yes. This template is one of 11 in the IVDR Performance Evaluation Kit, priced at €399 against €759 buying all 11 separately.
What software do I need?
Microsoft Word, or a compatible alternative that opens .docx files without reflowing tables.
Is this a one-off purchase?
Yes. The licence is for single-organisation use and the file is yours to keep.
Need the whole file?
This template is one of 11 in the coordinated kit.
The IVDR Performance Evaluation Kit ships the PSUR with the PMS Plan whose indicators it reports on, the PMPF Plan and Report and the full performance evaluation. €399 for the full set.
Periodic Safety Update Report (PSUR) Template — EU IVDR
One Word document, the Article 81 report with a conclusion that follows from the data.
€69.00